The R02 model records a reusable nicotine device in development. A dimension in CAD, a supplier drawing and a result from a physical test answer different questions. The decisions below state which evidence we have and what could change the design.
Reservoir geometry · Refill and airflow · Power and display · Contents and exposure · Engineering records
Why the reservoir is round
Decision. Use a cylindrical bore for the moving piston in the leading reservoir design. Evaluate a satin-white flat-front housing alongside the original cylindrical exterior. Both are prototypes.
- Seal geometry. At equal capacity and length, a circle and square have the same cross-sectional area A. Their perimeters are 2√(πA) and 4√A. The round bore therefore has about 11.4% less seal perimeter and no corners. A circular piston accommodates a ring seal with uniform nominal compression. Actual leakage, sticking and wear depend on the seal material, surface finish, tolerances and fluid. Measure them after storage and repeated refills. Parker O-Ring Handbook
- Heat transfer. The same comparison gives 11.4% less sidewall area. In a thin wall under steady conditions, the heat flow is approximately U × area × temperature difference, where U includes the relevant thermal resistances per unit area. At equal U and temperature difference, less heat crosses the cylindrical sidewall. That can slow both warming and cooling. End caps, nearby electronics, metal contacts and repeated use can change the result. Measure liquid, enclosure and board temperatures through use and cooldown.
- Pressure. Internal pressure puts a thin circular wall chiefly in circumferential tension. Flat panels also bend between their supports. This is a reason to evaluate a round pressure boundary. The actual pressure, joints, impact damage and relief behaviour determine whether there is a useful structural advantage here.
- Draw resistance. A circular duct has a theoretical flow advantage for steady, fully developed laminar flow through straight passages of equal length and area. Our intake holes, changes in section and heater complicate that comparison. Measure pressure drop versus airflow across the complete device, including with fingers near the inlet. Device airflow measurements
- Handling. Round bodies can roll. Compare grip, inlet blockage, drop damage and post-drop leakage against a flat-sided shell built around identical internals. The shell shape conveys no established health advantage.
Why the piston and refill are separate decisions
The follower takes up volume as liquid leaves. The proposed benefit is reduced replacement air contacting the liquid. Oxygen can still enter through materials, seals or the refill connection. Compare oxygen ingress, nicotine degradation, retained liquid and feed reliability against the vented and collapsible alternatives under the same storage and use conditions.
R02 uses a 12 mm bore and 16.25 mm working stroke, giving 1.838 mL theoretical displacement. The nominal geometric upper bound including manifold space is 1.873 mL. The external plunger can displace 6.338 mL from its illustrated position. That mismatch creates an overfill hazard. Metering, pressure limitation, measured delivered volume and leak containment remain open. The detachable head covers the refill connection; the concept calls for removal and electrical isolation before refilling.
Why add a display?
The white prototype uses a 1.14-inch EastRising ER-TFT1.14-2 colour IPS LCD. A 14.86 × 24.91 mm active area fits across the flat face and provides 135 × 240 pixels for readable status and fault information. The 25 mm grip leaves room for the carrier, rear fold and perimeter seal. A wider display would reduce the available width for the frame and its attachment. The graphite round version retains the smaller monochrome OLED for comparison. The Steam Deck influenced the clear separation of status, main reading and secondary information. Its larger display has different resolution, brightness and optical characteristics. Backlight power, thermal rise, cable termination and daylight legibility need physical testing. Supplier drawing · Valve display specifications · Display comparison · Flat housing fit
Show information the device can support. A qualified battery gauge could report charge level. Charge state, a service lock and a detected fault should each have a distinct text label. A temperature sensor reports temperature at its mounting point. Any claim about heater or aerosol temperature would need a validated relationship. Unknown readings should appear as “Unavailable.” A calendar reminder can prompt an inspection; a claim about seal wear or remaining liquid requires a validated measurement or estimate.
Let people change presentation settings. Brightness, text size and screen timeout are reasonable candidates. Prioritize readable faults, including for people who cannot distinguish colours. Reserve heater power, temperature limits, nicotine delivery and protection thresholds for engineering validation. The settings interface must have no route to override a fault lockout. A blank screen, frozen menu or failed display connection must leave the independent protection path effective. Acknowledging a message must never clear an active fault.
Account for the physical cost. A display competes with the board and cell for volume. Its window creates a new potential leak path and impact surface. Compare standby draw, charging heat, run time, daylight legibility and accidental activation with the indicator-only design. Test drops, cleaning-fluid ingress, condensation, failed sensors, stuck buttons, a disconnected screen and loss of power. Retain the display only if users recognize faults and take the correct action more reliably without a material increase in other risks.
Try the display interaction study. Changing the example condition updates the pixels on the assembled 3D model. Readouts are simulated.
Electrical decisions so far. The charger and protection IC packages follow TI drawings. Their fit and 23 board lands are modeled. Circuit routing, the external protection circuitry, cell, connector and thermal path are unresolved. The Molicel P28A was excluded because its manufacturer prohibits the application. The evaluated Würth receptacle conflicts with the existing mounting geometry. Neither part is installed in the model. Electrical packaging record
Why measure the contents and the aerosol?
Nicotine delivery and a familiar draw are product requirements for adults who already vape. Health takes precedence over flavour, sensation, finish and price. Apple ice remains a research candidate. Compare it with an unflavoured reference and evaluate flavour and cooling separately. Tests must follow the liquid through storage, repeated refills and heating to the aerosol at the mouthpiece. Track dose, carbonyls, metals and substances released from wetted materials. Compare emissions at comparable nicotine delivery and check whether reducing one exposure increases another. Long-term health and any claim of being first remain unproven. Scientific feasibility · Health Canada
Engineering records
- Complete project brief — health priorities, premium pricing, expertise, user experience, evidence standards and decision responsibilities.
- Reservoir requirements and R02 capacity and refill calculations — barrier materials, interfaces, usable volume, friction, overfill and unresolved tests.
- Head and airflow interfaces — inlet, liquid feed, chimney, condensate, screws, seals and access assumptions.
- R02 board integration and electrical candidate selection — component geometry, manufacturer evidence, design exclusions, calculations and electrical validation.
- Materials and surface review — why the digital finishes differ, which details follow drawings and which require process selection.
- Component specifications — function, candidate material, process, contacts and design basis for every catalogued part, including the refill and comparator assemblies.
- R01 mechanical decisions, fluid comparison and calculation audit — historical geometry and earlier limitations. Use the R02 fluid review for the current stroke and capacity.
When a choice changes, update its rationale, alternatives, evidence, limitations and next test on this site alongside the model or specification. Keep superseded values identified by revision.
Satin white outer housing
The flat-faced housing gives the display a planar mounting surface. Rounded sides soften the edges in the hand. The liquid chamber retains its circular bore for the existing sliding piston and circumferential seal. The external finish is confined to the grip, away from liquid and inhaled air.
The visual reference is the Charles Jackson cube. Its pale brushed panels, fine grain, narrow seams and chamfer highlights describe an appearance. The cube is a digital asset. A white pigmented finish on exterior metal is a candidate physical construction. Review witness samples under daylight and grazing light for gloss, edge coverage and visible wear before specifying a process.
For an opaque shell in direct sun, absorbed solar power is approximately incident irradiance times projected area times one minus solar reflectance. White can reduce absorbed solar energy when its reflectance across the solar spectrum exceeds the comparison finish. Visible shade alone gives incomplete information, particularly in the near infrared. Thermal infrared emissivity also affects cooling. Internal heating during operation and charging requires separate measurements. Berkeley Lab cool surfaces
Compare white and graphite finishes on otherwise identical housings under matched irradiance, orientation, ambient temperature, airflow and electrical load. Record solar reflectance, grip, cell, electronics and reservoir temperatures over time, with a shaded control. Repeat after cleaning and abrasion. Examine adhesion, chipping at seams, sweat resistance and coating buildup at the window recess. Compare body shapes separately. These measurements can establish a temperature difference under the test conditions. Inhalation risk requires separate aerosol and exposure evidence.
Grip and proportions
The broad, flat display face and rounded rear corners of the SMOK NORD 6 are a handling reference. The reference photograph establishes neither internal dimensions nor comfort. Our own CAD grip measures 25.00 mm across and 22.40 mm deep, with a 2.85 mm front corner radius and 5.20 mm rear radius. The modeled window sits 0.07 mm below the front face. The radii and recess are starting dimensions for a physical comparison.
Make inert, weighted samples of both body profiles. Match the target mass and balance with the reservoir full and near empty. Check both hands across hand sizes, with dry and damp fingers. Observe pressure points at the base and back corners, unintended inlet coverage, screen visibility, slipping during pickup and whether the grip must shift to read a fault. Choose final radii and texture from those observations.
Markings and surface detail
The lower grip carries the prototype identifier R02/F. Two short index marks meet across the waist when the housing sections align. Each mark belongs to its own sleeve and follows that sleeve in the exploded view. The marks sit on external faces, clear of the window, fasteners, seal seats and liquid path. The letters and symbols are original artwork.
The Charles Jackson cube uses a recessed panel face with a raised perimeter, a bank of slots and compact part markings. On this device, the upper sleeve carries a shallow machined field. Light catches its beveled rim as the sleeve turns. The parallel channels end in solid material, and the existing housing vent has its own bore below the field. The exterior reads “Vape Research” on one line. Smaller condensed lettering leaves a clear margin on either side of the recessed panel. Engineering drawings use the part code C02, which can resemble the chemical formula for carbon dioxide. The panel detail belongs to the sleeve, so it moves with that part in the exploded view. Verify wall thickness, machining tolerances, cleanability and coating coverage on a physical sample. Inspect the sleeve
Fine grain breaks up the highlight on the white grip. A separate directional finish wraps the narrow titanium waist. The upper shoulder uses surface normals taken from the CAD loft so the highlight follows the transition into the circular head. Physical appearance and durability still depend on the eventual coating and finishing process. Inspect the grip · Inspect the waist
Mouthpiece shape and exposure
Keep the circular internal passage as the comparison baseline. The satin-white study uses a softly flattened exterior with rounded lip-contact edges around the same passage. The original round tip remains available for comparison. Inspect the flattened tip · Inspect the round tip At a fixed volumetric flow, mean exit speed equals flow divided by open area. Round and oval openings of equal area have the same mean speed under that assumption, while their velocity profiles and resulting jets can differ. The current tip has no demonstrated health advantage. A dry-powder inhaler study compared cylindrical, conical and oval mouthpieces. Separate e-cigarette experiments measured nicotine delivery in a mouth–throat replica under different conditions. Neither establishes a healthiest vape tip. Mouthpiece geometry study · E-cigarette exposure study
Compare outer shapes on inert samples for lip comfort. Separately bench-test draw resistance, lip-contact temperature and liquid carryover after repeated draws and tilting. Measure aerosol at the outlet and downstream of a mouth–throat replica. Less material collected in the throat can leave more available to reach the lungs.
Surface treatment by component
On the reference cube, fine grain and sparse directional marks vary the roughness of bare metal. The white housing uses a quieter directional satin texture appropriate to its coated exterior. Its titanium waist has a separate brushing direction. The uncoated, mineral-grey mouthpiece uses a softer highlight. The white prototype carries its satin exterior across the broad intake collar to the mineral-grey tip. A narrow titanium line identifies the removable joint. Keep the inlet bores and edges clear of decorative coating; assess process masking, adhesion, heat cycling and possible transfer before choosing the physical finish. Clean cylindrical shading around the drilled inlets lets the rim of each hole catch light individually.
The underside carries a BASE identifier away from the charging aperture and fasteners. Inside the device, the passivated fasteners, moulded supports, ceramic, glass, terminals and elastomer seals retain their distinct surface responses. Purchased chip packages carry their documented identifiers. Optical openings, contacts and wet surfaces are kept free of decorative ink. The register lists the actual exported material assignments for each part in the white study. Component finishes
Heat, humidity and cold
The vulnerable moment can be entering warm, humid air after the device has been cold. If the housing or circuit board is below the air’s dew point, water can condense there. A dry-looking screen is insufficient evidence that the interior or charge connector has dried. Qualify water ingress and internal condensation separately. Cold charging can deposit metallic lithium in a lithium-ion cell; charging limits must follow the selected cell and measurements of its actual temperature. TI charging-temperature guidance · IEC cyclic damp heat · Climate design and test plan
Mouthpiece filtration
The white-model cartridge uses a track-etched polycarbonate film between two supports. A perimeter seal surrounds the film and a second seal closes the path around the cartridge. The open bore remains the reference. Compare both joints with an impermeable witness at matched pressure before interpreting any change in draw or metal delivery. Inspect the optional insert · Filter test plan
Heat can break down liquid ingredients into compounds such as formaldehyde. Metals can enter the aerosol from device components. Reducing metal release at the source and controlling heater conditions address different problems. Metal source investigation · Heating and aldehyde measurements
A particle filter could intercept some metal-bearing particles. Metal dissolved in a liquid droplet can pass with that droplet, and a particle filter can also capture the droplets that carry nicotine and flavour. Gas-phase compounds can pass through. A vaping-machine study measured condensate capture and airflow with nicotine-free liquid. Whether a compact insert can selectively lower exposure while preserving the draw remains an open question. Metal-containing particles in pod aerosols · Condensate collection experiment
Compare the same device with and without the insert. At the mouth end, measure metals per puff, nicotine delivery, droplet size and gas-phase aldehydes. Record the pressure needed for the same airflow when the insert is fresh and after condensate builds up. Check for released fragments or chemicals, liquid breakthrough and leakage at both seals. A candidate should advance only if its benefit persists through its intended service life at comparable nicotine delivery and acceptable draw resistance. Sensory equivalence and long-term health effects are separate questions.