R01 mechanical, fluid and thermal calculation audit

The reference section locates the chamber, air path and power cassette.
R01 archive · Geometry used for calculationsThe reference section locates the chamber, air path and power cassette.Inspect the reservoir ↗

These are nominal calculations from the modeled shapes. Reproduce them with python3 models/r01/calculate.py at the project root. The script verifies source dimensions and independent length/flow identities and writes calculations.json with full precision, units and source SHA-256 fingerprints. Figures below are rounded. The primary cartridge, external refill and electrical assembly are separate systems.

Liquid space, swept volume and retention

The fluid model places the F01 barrel bore at 12.00 mm diameter. Its working area is π × 6² = 113.097 mm². F02 ends at z57.80. F04 extends into the barrel to z81.00. The piston lands and gland span 0.85 + 1.25 + 0.85 = 2.95 mm. The visible barrel length includes these solid intrusions.

Measure Nominal calculation Meaning
Absolute geometric stroke 81.00 − 57.80 − 2.95 = 20.25 mm Stroke if perfectly flat end surfaces contact both hard stops.
Full swept volume 113.097 × 20.25 / 1000 = 2.290 mL Upper limit for displacement in the bore. No fill allowance, intentional end stop, reserve or use condition has been approved.
Sweep from the illustrated position 81.00 − (59.50 + 2.95) = 18.55 mm, or 2.098 mL As-modeled follower starts 1.70 mm from the rear stop.
Working-margin sensitivity 0.1131 mL per mm of unused stroke Subtract the total unavailable travel from 20.25 mm to estimate reduced geometric sweep.
Fixed outlet bore π × 0.60² × (86 − 81) = 5.65 µL Liquid passage within the manifold.
Refill-side blind passage π × 1.35² × (82.60 − 81) = 9.16 µL Branch upstream of the relaxed refill septum.
Modeled fixed main passages 14.82 µL combined These volumes lie outside the piston's sweep. Wet films, seal crevices, annular fits, elastic movement, the wick, ferrule, ports and actual drainage alter retained liquid.

Refill stroke is a mechanical limitation. The external F10 bore diameter is 17.60 mm. Its area is 243.285 mm². With the follower at z15, the nominal liquid chamber above the piston can hold 6.338 mL before accounting for details at the outlet. In the current assembly the F16 thumb pad spans z4–5 and F12 starts at z9. A forward motion of 4.00 mm brings the pad against the stop. This restricts displacement from the illustrated position to 0.973 mL, even with zero friction or leakage. The geometry calls for additional actuator travel or a revised refill mechanism if one stroke must replenish the primary chamber. Measure delivered mass, leaked and retained mass, and actual stroke with the intended valve and fluid before assigning a refill or usable-capacity rating.

Pressure, force and vent sensitivity

Force on a piston is differential pressure times bore area. Each kPa across the primary piston corresponds to 0.1131 N; each kPa across the refill follower corresponds to 0.2433 N. These are conversion factors. Actual actuator force also includes seal breakaway and running friction, side load, and any valve-opening force. Available capillary suction, head elevation and line losses determine whether the primary follower can move. No measured friction, contact angle, permeability or liquid viscosity is available.

The chassis source gives a side vent of 0.84 mm diameter at z55.18. Model air following approximately 10.50 mm of radial passage and 2.62 mm of 1.30 mm axial passage up to z57.80. For steady, incompressible, fully developed laminar flow in ideal circular tubes, resistance is 128 μL/(πd⁴). With illustrative air viscosity 0.000018 Pa·s, the combined slope is 16.14 Pa per mL/s. Reducing only the radial diameter by 20% brings the slope to 38.43 Pa per mL/s. The flow unit is a normalization for sensitivity. It is not an intended device flow or user draw rate. This vent supplies displacement volume behind a follower. The head has a separate inhalation path.

The estimate excludes entrance losses, short-bore and bend effects, gas compression, fouling, exterior grip obstruction, leakage at the bulkhead joint and capillary blockage by droplets. Test response under pressure ramps during refill and simulated draw cycles, including one obstructed or wet vent. Measure actual flow and pressure before assigning cutoffs or reserve margins.

Seal, alignment and electrical route

Interface Nominal result Limit that needs verification
Dynamic piston gland Depth 0.80 mm against free section 0.95 mm gives 15.79% squeeze. Cross-sectional fill π × 0.95² / (4 × 0.80 × 1.25) = 70.88%. Approximation ignores free-ID stretch, tolerance, swelling, compression set, lubrication and pressure extrusion. Measure insertion, breakaway and cycling on actual seals.
Primary land/bore 0.10 mm radial clearance. Establish eccentricity, straightness and allowable glass load with the installed seal.
Refill pilot/bezel (2.40 − 2.10)/2 = 0.15 mm radial clearance. Alignment, user tilt, aperture finish, tolerance and wear consume that margin.
Head gasket/outlet (1.64 − 1.20)/2 = 0.22 mm radial opening margin. Worst-case component eccentricities must fit within the functional margin. Gasket clamping force needs a controlled axial stack.
Core/jacket/bushing Nominal radial gaps 0.003 mm core-to-jacket and 0.002 mm jacket-to-bushing. Bushing OD-to-bore clearance is zero. Envelope model for an insulated conductor. Neither a 2 µm fit nor a pressure-tight gland is substantiated by packaging dimensions. Specify the supplier construction, dielectric integrity and retention.
Ledge keyway/jacket Half-width 0.68 − jacket radius 0.38 = 0.30 mm per side when centred. Account for bend radius, lead placement, abrasion protection, movement and actual tolerances.

For two diameters with bilateral diameter tolerances ±T₁ and ±T₂, the worst-case radial gap decreases by (T₁ + T₂)/2 before offset, ovality, coating growth or thermal movement. A positive nominal gap alone supplies no tolerance guarantee. The power geometry shows component, conductor and terminal envelopes. A PCB schematic, real cell, control strategy, charger selection, connector qualification and verified sensing or independent shutdown are outstanding.

Winding geometry, candidate resistivity and energy balance

The head generator forms a winding centreline with radius 1.49 mm, pitch 0.84 mm and five turns. Its polyline has 240 segments totaling 46.9645 mm. An independent smooth-helix calculation gives 46.9978 mm, a difference of 0.071%. The modeled wire diameter is 0.30 mm, or 0.070686 mm² of metal. HD08/09 terminations are separate. The winding label alone leaves the alloy unspecified.

As one material scenario, Kanthal lists Nikrothal 80 wire at 1.09 Ω·mm²/m at 20°C, density 8.30 g/cm³ and a 100°C resistance factor of 1.01. Substituting this candidate into R = ρL/A gives a coil-only 0.7242 Ω at 20°C and 0.7315 Ω at an illustrative uniform 100°C. The uniform-wire mass is approximately 0.02755 g. The temperature pair shows sensitivity to material state. It is neither a process set point nor a rating. These numbers exclude leads, joint resistance, wire tolerances, wetting variation, corrosion, partial shorts and temperature gradients. Verify actual alloy, impurity release, compatibility and cold/hot four-wire resistance before selecting a material. Kanthal wire data

For a measured terminal current I(t) and voltage V(t), delivered electrical energy is the time integral of VI. For a resistive winding, the corresponding modeled winding energy is the integral of I²R(T). Within an initially uniform, passive control volume with no other energy source, the Joule energy bounds the portion available to heat components and evaporate expelled liquid. For example, an upper estimate of evaporated mass from that input is E/Lᵥ if sensible heating and losses are neglected. An idealized uniform insulated winding would satisfy ∫m cₚ(T)dT = E. Neither relation bounds the local hot-spot temperature for an unknown heat distribution. Real stored heat, heat lost to the housing and air, convection, liquid delivery, phase change and changing wick contact all affect the result.

Required inputs include I(t), V(t), selected cell and protection limits, thermal properties, time-varying wetted area, fluid composition and latent heat, delivered liquid mass, effective heat capacities, thermal contact resistances and measured fault response. Geometry supplies none of the required qualification evidence for a safe operating power, allowable temperature, battery life, nicotine dose, exposure or human use. Synchronize bench temperature, current, pressure-flow and chemical emission measurements before drawing those conclusions.