Heating head
Liquid leaves the reservoir through a sealed feed and reaches a porous ceramic wick. A resistance winding around the wick supplies heat. The surrounding collar admits air through small side openings, where it meets the heated aerosol before entering the chimney.

Heating head
Assembled
Installed positions
Scroll to separate the parts, then follow each numbered marker.
Design science
Evaporation carries heat away from a wetted wick. If liquid arrives too slowly, a section of winding can run hotter even at the same electrical power. Uneven wetting and contact resistance can create local hot spots. Heating can generate carbonyls from liquid ingredients, while metal from components can also enter the aerosol. The winding in the model shows electrical connections. Its power, temperature and emissions are still unmeasured.
What needs testing
Measure winding temperature at several locations during repeated machine draws with full, nearly empty and interrupted feeds. Record actual electrical input, airflow and liquid consumption. Collect aerosol at the mouthpiece for carbonyls, metals and nicotine, including after the head ages. Check that a feed fault stops heating before selecting an operating range.
Inner parts and interfaces
HD02Feedthrough carrier
Locates the liquid feed and electrical contacts and fastens the head to the housing.
The deck gives the head a common mounting surface for the central liquid feed and the two electrical contacts on either side.
Inspect part ↗
HD13Outlet face gasket
Seats between the reservoir outlet and the head to limit liquid leakage.
The gasket sits at the joint that opens when the head is removed. Its annular face leaves the liquid feed open while applying a seal around that opening.
Inspect part ↗
HD03Liquid feed ferrule
Directs liquid from the reservoir outlet toward the wick.
The ferrule aligns the narrow feed from the reservoir with the base of the porous wick, where liquid enters the heating head.
Inspect part ↗
HD04Capillary wick
Draws liquid toward the proposed heater through its porous body.
The porous wick sits between the feed and the winding so capillary action can replenish liquid at the heated surface. Feed rate during repeated draws still needs testing.
Inspect part ↗
HD05Wick heater winding
Represents the resistance element wrapped around the wick.
Wrapping the resistance element around the wick places heat at the surface that supplies liquid. The model establishes the winding route; actual temperature uniformity needs measurement.
Inspect part ↗
HD08Lower heater termination
Joins the lower end of the heater winding to contact HD06.
The lower lead bridges the short distance from the start of the winding to its deck contact. This joint needs checks for contact resistance and local heating.
Inspect part ↗
HD06Insulated-deck contact
Connects the lower heater termination to the dry-side electrical pad.
One contact passes through the deck beside the central liquid feed, directly below the short lead from the lower end of the winding.
Inspect part ↗
HD09Upper heater termination
Joins the upper end of the heater winding to contact HD07.
The upper lead climbs beside the wick, then reaches across to the far end of the winding. Its closest approach to the chimney needs a tolerance and insulation check.
Inspect part ↗
HD07Insulated-deck contact
Connects the upper heater termination to the opposite electrical pad.
The second contact sits on the opposite side of the feed so the longer lead from the upper winding has its own connection through the deck.
Inspect part ↗
HD01Air inlet collar
Surrounds the atomizer and admits air through rows of side holes.
Side openings bring air into the space around the wick before the stream enters the chimney. Their resistance needs measuring with the device held in a hand.
Inspect part ↗
HD14Deck retaining socket screw
Clamps one side of the feedthrough deck to the housing ledge.
The first deck screw sits outside the liquid feed and beside the electrical interfaces. Removing the chimney exposes its head for straight tool access.
Inspect part ↗
HD15Deck retaining socket screw
Clamps the opposite side of the feedthrough deck to the housing ledge.
A screw on the opposite side lets the deck clamp against its mounting ledge at two locations. Preload and the resulting gasket compression need measurement.
Inspect part ↗