Control board
Four stand-offs locate the board behind the cell. U1 is a candidate TI BQ24075 charger and power-path controller. U2 is a candidate TI BQ29700 single-cell protector. The model places their packages on 23 copper lands derived from TI’s example footprints.

Control board
Assembled
Installed positions
Scroll to separate the parts, then follow each numbered marker.
Design science
The charger manages power from the external supply and charging current to the cell. The protection IC monitors cell faults and requires external switching circuitry. Heat must travel from the charger through its exposed pad into the board. A pad outline alone cannot establish how much heat the finished board can remove.
What needs testing
Complete the schematic, copper routing, thermal layout and external switches. On instrumented hardware, measure charger temperature and verify current limiting, fault cut-off and recovery against the selected cell’s specifications. The scientific record currently establishes package dimensions and nominal placement.
Inner parts and interfaces
PWR-022Control-board substrate study
Proposed board substrate and mask with 23 copper lands from TI example board layouts, including the charger thermal pad. U1 and U2 locate the candidate devices. Copper routing and solder joints still need design.
Placing the substrate behind the cell uses the remaining depth of the bore. Its 23 copper lands allow the two proposed IC packages to be checked against their footprints.
Inspect part ↗
TI-BQ24075RGTRbattery charger and power-path IC
Texas Instruments BQ24075RGTR candidate battery charger and power-path IC. The package body and terminals follow the manufacturer drawing. Placement is provisional; the circuit has not been designed or validated.
This candidate combines single-cell charging and power-path management. Its exposed thermal pad makes the board copper layout part of the thermal design.
Inspect part ↗
TI-BQ29700DSERsingle-cell protection IC
Texas Instruments BQ29700DSER candidate single-cell protection IC. The package body and terminals follow the manufacturer drawing. Placement is provisional; the circuit has not been designed or validated.
A separate protection IC gives the proposed cell its own fault-monitoring function. Its external switches, thresholds and compatibility still need to be checked against a selected cell.
Inspect part ↗
PWR-048Board stand-off
Spaces the board from the cradle at its first lower mounting point.
This lower support sets the first stand-off distance between the board and internal cradle.
Inspect part ↗
PWR-049Board stand-off
Spaces the board from the cradle at its first upper mounting point.
Supporting the upper end of the same board edge limits the unsupported span along its length.
Inspect part ↗
PWR-050Board stand-off
Spaces the board from the cradle at its opposite lower mounting point.
A stand-off on the opposite lower corner supports the board across its width and establishes its mounting plane.
Inspect part ↗
PWR-051Board stand-off
Spaces the board from the cradle at its opposite upper mounting point.
The fourth stand-off supports the opposite upper corner so the board can seat against the carriage at both ends.
Inspect part ↗
PWR-052Heater output terminal land
Provides the board connection for the first heater lead.
A designated land gives the first heater lead a defined termination and a reference for future routing and joint inspection.
Inspect part ↗
PWR-058Heater output terminal land
Provides the board connection for the second heater lead.
A second terminal land keeps the two heater connections distinct on the board and gives the return path its own attachment point.
Inspect part ↗