The flat and pleated cartridges place the same thin polycarbonate film beneath the mouthpiece. The open bore is our reference. We want to find out how much suction each cartridge adds, whether aerosol escapes around the seals, and what reaches the mouth. Both are untested research designs. Compare the inserts in 3D
Estimated draw resistance
Both inserts fit the same white body and use the same nominal 1 µm polycarbonate film. The disc stretches across the bore. The alternative folds the film around a central passage, giving the aerosol more surface to cross at the same flow. The geometric comparison favours the pleat for a bench prototype. How much suction either finished cartridge requires, and which metals reach the mouth end, remain open questions. Rotate and compare the two inserts
Estimated extra suction across the film at the selected airflow
At equal fractional blockage, this model gives the pleated film 4.2% of the pressure drop across the disc film.
The bars compare film pressure alone. The open bore already requires suction. The pleat adds flow turns, narrow valleys, a collection core and openings in its supports. Their losses must be measured. All bars use the same scale as you change the airflow or blockage.
Area in the calculation. For the disc we use 10.75 mm² through the grid that touches the film. The full seal aperture is 19.01 mm² and the two support grids overlap over 6.71 mm². A 34 µm outlet clearance allows some sideways flow. For the pleat we use 257.53 mm², calculated from the CAD geometry after excluding both sealed ends, the longitudinal seam and the angular sectors shaded by support ribs. The 16-pleat wall has 299.20 mm² of gross film and 267.55 mm² after the ends and seam alone. Both calculations assume even access to the available film. At 1 L/min the corresponding dry face velocities are 1.55 m/s for the disc and 0.065 m/s for the pleat. The central outlet has only 3.63 mm² of clear section, corresponding to 4.6 m/s at that same flow. The ratio of available film areas is 24.0 to one. Inspect the disc supports · Inspect the pleated cartridge
How we estimate suction. We assume identical dry film from the same lot and resistance proportional to flow per open area. The chart uses Δp = 68.95 × Q / (20 × A × f) kPa, where Q is flow in L/min, A is accessible area in cm² and f is the fraction still passing air. The constants come from the manufacturer's minimum roll-acceptance flow at 10 psi under positive pressure. Using that single point as a linear slope is a screening assumption. Gas compression, test conditions and lot variability limit its use at mouthpiece suction. The absolute numbers are illustrative. Low-pressure permeability and whole-device pressure–flow curves need to be measured. GVS sheet specification, page 3
What “wet” means here. A setting of 50% assumes half the available film stops passing air and the remainder behaves as dry film. It doubles the calculated film pressure at a fixed flow. Equal puff counts or equal condensate mass can produce different blockage in each design. Liquid can bridge opposing fold faces or flood the outlet. Try greater blockage for the pleat than for the disc to see the effect. If about 96% of pleated paths close while the disc stays dry, the geometric advantage disappears in this model. Full blockage leaves no through-film path in this model.
The wet bench comparison. Test the open device, each empty holder, and each loaded cartridge. Randomize matched runs across units and film lots. Use the same mouth-end flow waveform, temperature, orientation and aerosol challenge. Record pressure and actual flow continuously, and weigh each cartridge before and after exposure. Compare both at equal cumulative aerosol exposure, then separately at matched retained condensate mass. Repeat after drainage and at end of service. Look for sharp pressure jumps, flow interruptions, leakage and liquid carryover. Compare at matched suction as well, since a person can respond to extra resistance by drawing less flow.
Does it still capture metals? Folding changes face velocity even with identical pores. For the open bore, disc and pleat, measure downstream metal mass per puff and per drawn litre, plus particle number by size and elemental composition where measurable. Match the entering aerosol across runs and distinguish dissolved metal in droplets from discrete particles where the method permits. Measure nicotine, flavour markers, droplet size, film or seal fragments, and gaseous carbonyls separately. Check bypass around the perimeter, pleat end seals and longitudinal seam. A lower modelled pressure drop alone establishes neither metal capture nor equivalent nicotine delivery. Primary measurements of metal-containing particles
How the flat film is supported and sealed
The drawing uses GVS sheet 1224067, a PVP-free track-etched polycarbonate film with nominal 1 µm pores. The supplier specifies a thickness of 10–12 µm. The model uses an 11 µm section cut to a 5.76 mm disc. The pores are a material specification; their individual geometry is below the display scale. The supplier sheet calls this grade hydrophobic but lists hydrophilic wetting in its properties table. Confirm the delivered lot’s surface treatment and measure its behaviour with the actual condensate before making any wetting assumption. GVS grade specification
| Part | What it does |
|---|---|
| Carrier and outlet grille | The film rests on the carrier’s upstream grid. The downstream grid, rotated a quarter turn, limits deflection across the slots. Its ribs sit 34 µm above the unloaded film. A formed lip retains the grille against a fixed shoulder. |
| Film and edge seal | The 0.250 mm free-thickness edge seal closes to 0.200 mm against a continuous annulus of film on a solid backing land. The 4.92 mm seal opening exposes 19.01 mm² before the support ribs are accounted for. |
| Bore seal | A separate ring of 0.50 mm free cross-section occupies a 0.40 mm radial gap between groove floor and bore. Both joints have 20% nominal squeeze. Contact pressure and variability require physical tests. |
If either joint leaks, the draw can feel easier because some aerosol avoided the film. The fit drawing establishes the intended contact geometry. Bypass, capture, shedding and draw resistance all require measurements on finished samples. Zoom in on the two seal contacts · Full-size section and exploded drawing
Which material to test first
The bench candidate is a continuous perforated sheet. Its lack of loose fibre ends removes one possible shedding mechanism. The cut edge, supports and seals still need screening for particles and chemicals released into condensate. Manufacturer’s description of the film
| Candidate | Evidence and decision |
|---|---|
| Track-etched polycarbonate film | Air-sampling experiments found that some nanoparticles deposited inside pores and others passed through. The selected research grade still needs testing in the finished insert at its actual flow and after wetting. Capillary membrane experiment |
| PTFE membrane | A useful comparison for particle capture and pressure loss. Performance varies with the grade and flow velocity. Specify whether a support layer is present and test the entire assembly after wetting. Comparison of membrane and fibre filters |
| Polyester fibre fill | An e-cigarette investigation found tin trapped in fibre fill and tin particles still leaving the device. This is evidence of partial retention. It leaves fibre release, nicotine delivery and flavour unanswered. Use as a research comparison only. Metal source investigation |
At an illustrative 1 L/min, flow through the 19.01 mm² seal opening corresponds to about 88 cm/s before accounting for support ribs. Each seven-slot support has 10.75 mm² of geometric opening, giving about 155 cm/s averaged over those slots at the same flow. The two support patterns have 6.71 mm² of direct projected overlap. Air can also flow laterally; none of these geometric areas predicts pressure loss by itself. Verify the pressure drop with the finished support pattern, especially as condensate accumulates. A capillary-membrane experiment used face velocities of 3.7 and 18.4 cm/s. Its results cannot be directly transferred to this compact holder and warm, condensate-laden aerosol. Study conditions
Does air bypass the film?
- Measure fixture leakage first. Cap the empty test fixture to measure its background leak and detection limit. Check the instrument with a known small leak and record its uncertainty.
- Block the intended flow path. Replace the porous film with an impermeable witness disc of matched thickness, diameter and surface finish. Keep both seals, supports, stops and assembly preload as in the working cartridge. At the same pressure differences measured during draws, record how much air still reaches the mouth end. Measure the complete porous insert at those same pressures. The ratio of blank flow to fitted flow estimates bypass if the change of disc preserves seal contact.
- Locate any leak. Test the film-edge joint in a fixture that seals the outside of the carrier independently. Then test the cartridge-to-device joint with the carrier bore independently blocked. Measure each fixture’s own background. This separates a leaking film rim from a leaking cartridge seat. Repeat after routine installation, removal, wetting, drying and service ageing, including representative tolerance extremes.
- Decide using a bound. Set an allowable bypass fraction before testing, based on the target metal reduction and the uncertainty of the measurement. Report an upper bound when leakage is below detection. Inspect the real porous film after assembly for tears or wrinkles and repeat the outlet aerosol test. The impermeable witness alone cannot reveal damage to a production film.
Measuring the complete draw
Use a calibrated puff machine to replay the same flow over time. Match the liquid batch, fill level, heater setting, starting temperature and puff interval. Measure the actual flow and volume at the mouth end. Keep the collection tubing and its resistance identical. Measure the extra suction required at each flow. Also calculate work per puff from the pressure difference integrated over drawn volume. For a second series, apply the same suction waveform to all three configurations and compare the resulting flow trace and puff volume. Also test each empty holder to isolate losses introduced by its supports and passages.
Pair runs within each device and counterbalance their order. Use independent devices, heads and insert lots. Control residual deposits between runs and balance head age across the two conditions. Repeated draws on one unit measure how it changes with use. Several independent units are needed to estimate device-to-device variation.
What to measure
| Question | Primary reading | How to interpret it |
|---|---|---|
| Do fewer metals leave the mouthpiece? | Collect aerosol at the outlet and account for deposition in the collection path. Quantify target elements such as nickel, chromium and lead by ICP-MS, an elemental mass analysis. Report nanograms of each element per puff. | Compare each element across paired runs. Collect known-volume blocks of puffs. Include collection-train blanks, recovery checks and limits of quantification. An undetectable baseline cannot establish a percentage reduction. |
| Is the draw mechanically equivalent? | Measure pressure from ambient air to the mouthpiece against actual flow, in pascals at matched litres per minute. Record the peak and the pressure trace through the draw. | Compare the pressure–flow curves over the intended range. A comfortable first draw could become restrictive as condensate collects. |
| Is nicotine delivery comparable? | Measure nicotine mass per puff and total aerosol mass per puff. Also report nanograms of each metal per milligram of delivered nicotine. | A lower metal reading can accompany a weaker puff. Read absolute metals, nicotine and the normalized ratio together. |
Sample fresh, condensate-loaded and end-of-service inserts. Define the loading conditions and replacement interval before the comparison. Include the expected humidity and orientation range. Record early blockage, bypass at the carrier edge, retained liquid reaching the mouth end, and particles or extractables released by the film, seals or supports. Include clean-air and condensate blanks. Identify detected fragments, quantify individual flavour markers in the outlet aerosol and report analytical detection limits.
What would count as a benefit?
Before confirmatory testing, name the target metals and define a meaningful minimum reduction for each. Set equivalence margins for draw resistance and nicotine delivery using independent baseline measurements, instrument precision and an explicit rationale for what a user might notice. Use pilot variability to choose the number of independent devices. Publish the margins and analysis plan before assessing the confirmatory samples.
For each load state, report paired differences or ratios and confidence intervals across devices. Advance a candidate only if the intervals support the prespecified metal reductions and stay inside the draw and nicotine margins. Report every target, including increases and inconclusive results. A result close to the detection limit or an interval that spans the decision limit leaves the question open.
Check aerosol droplet size and collect gas-phase carbonyls in a separate validated sampling run. A particle filter may intercept nicotine-bearing droplets as well as metal-bearing particles. Gas-phase contaminants can still pass.
Would a person notice?
A machine measures resistance. An ethically reviewed, blinded crossover study would address perception only after material, exposure and retention review. Adults who already vape would compare visually and externally identical mouthpieces in randomized, counterbalanced order. First, a nicotine-free, unheated airflow comparison could isolate perceived draw effort. Assessing flavour, warmth or throat sensation would require its own approved aerosol comparison.
Make perceived draw effort the primary sensory endpoint. Have each participant rate it immediately after each coded condition on the same anchored scale. In an independent calibration, use graded reference restrictions to find when participants begin to notice a difference. Use those results to set the acceptable range for the difference in ratings. Size the study for that margin before collecting the confirmatory ratings. Record actual puff flow and volume to identify compensation.
For a prespecified two one-sided equivalence test at 5% per side, require the 90% confidence interval for the paired mean rating difference to lie wholly inside both margins, alongside passing mechanical and bypass results. A statistically inconclusive difference cannot establish that the two feel the same. Flavour and nicotine delivery each need their own result.
Why test the mouth end?
Olmedo and colleagues measured metals in refill liquid, tank liquid and aerosol from users’ devices. Pappas and colleagues detected metal-containing particles in aerosols from several pod systems. These findings support collecting what actually leaves the mouthpiece. Total elemental mass and particle count answer different questions. Liquid and aerosol measurements · Metal-particle measurements
Stephens and colleagues measured condensate collection and changes in airflow using nicotine-free liquid and a vaping machine. Their experiment illustrates why both measurements matter. The performance of this proposed compact insert remains unknown. Condensate collection experiment